Water Heater Parts Plastic Flow Sensor Hall Sensor Water Flow Sensor Switch
The sensor innovatively integrates a self-cleaning wiper design, where the impeller automatically clears impurities from the flow channel with each rotation, preventing scale buildup from affecting sensitivity. The built-in chip features a temperature compensation algorithm that eliminates detection errors caused by water temperature changes, maintaining ±2% flow detection accuracy within a water temperature range of 4-90°C. It supports four sensitivity levels (switchable via magnetic rod proximity), compatible with the startup flow requirements of water heaters with different power ratings. The dual-signal output design (pulse signal + switch signal) allows direct connection to the mainboard or use as an independent water flow switch.
Features
⚙️ Dual-Mode Output System
-
High-precision pulse mode: 2160 pulses per liter of water, resolution of 0.46 mL
-
Switch mode: adjustable startup flow (four levels: 0.3/0.5/0.8/1.2 L/min)
🌡️ Intelligent Temperature Compensation Technology
-
Built-in NTC temperature sensor for real-time compensation
-
Full water temperature range accuracy of ±2% (industry standard ±5%)
🛡️ Triple Dynamic Protection
-
Self-rotating scale-cleaning impeller (Patent No. ZL2022103****)
-
Ceramic bearings, never corrode
-
Shock-resistant structure passes 100g mechanical impact test
🔌 Fully Compatible Interface
-
Output interface: 3-wire system (VCC/GND/Signal)
-
Connector: JST 2.5mm pitch / optional wires
-
Operating voltage: wide voltage range of DC 3.3-24V

Product Parameter
| Item | Technical Specifications |
|---|---|
| Model | FS-2208H |
| Detection Principle | Hall Magnetic Induction |
| Housing Material | PPS + 30% Glass Fiber (UL94 V-0) |
| Impeller Material | POM Magnetic Ring Integrated Molding |
| Flow Range | 0.3-10 L/min |
| Startup Flow | Adjustable Four Levels: 0.3/0.5/0.8/1.2 L/min |
| Output Signal | Pulse Frequency: 0-360Hz (Linear) |
| Signal Output | Open Collector (Maximum 100mA) |
| Accuracy Class | ±2% FS (with Temperature Compensation) |
| Pressure Resistance | 1.6 MPa Burst Pressure |
| Operating Temperature | Medium Temperature: 4-95°C; Ambient Temperature: -20-85°C |
FAQ
Q1: How does the sensor prevent scaling in hard water areas?
A: It employs three anti-scaling technologies:
-
Impeller coated with nano-hydrophobic coating
-
Flow channel mirror polishing (Ra0.2μm)
-
Automatic high-speed self-cleaning twice a month (impeller idling at 3000 rpm)
Q2: How to determine if the sensor is faulty?
A: Diagnosis can be performed using the following methods:
-
Normal state: Multimeter detects pulse voltage fluctuations (0-Vcc variation) when water flows
-
Faulty state: Constant high/low voltage level
-
Reduced sensitivity: Significantly increased flow required for startup
Q3: What should be noted during installation?
A: Key installation requirements:
-
Must be installed horizontally (tilt <5°)
-
Water inlet direction must align with the arrow indicator
-
A 100-mesh filter is recommended upstream
-
Avoid installation at the highest point of the pipeline (to prevent air accumulation)
Q4: Can it replace mechanical water flow switches?
A: Fully compatible replacement with advantages including:
-
No mechanical contacts, lifespan increased by 10 times
-
Adjustable startup flow (fixed for mechanical switches)
-
Provides flow data instead of just switch signals
Q5: How to adjust sensitivity on-site?
A: Steps for adjustment without disassembly:
-
Use the included magnetic rod to approach the marked area on the sensor
-
Each approach switches to the next level (LED indicator flashes for feedback)
-
Four-level cycle: Green light (0.3L) → Blue light (0.5L) → Yellow light (0.8L) → Red light (1.2L)