Leave Your Message

Water Heater Parts Plastic Flow Sensor Hall Sensor Water Flow Sensor Switch

The water heater-specific plastic flow sensor is an integrated design using PPS high-temperature engineering plastic and Hall magnetic sensing technology, specifically developed for real-time water flow monitoring inside water heaters. Through the non-contact coordination of the impeller magnetic ring and Hall element, the sensor accurately captures water flow changes ranging from 0.3 to 10 L/min, generating 2160 pulse signals per liter of water. The triple-seal structure (O-ring silicone gasket + ultrasonic welding + epoxy potting) achieves an IP68 waterproof rating, capable of withstanding long-term exposure to 95°C high-temperature hot water. The internal flow channel is optimized through CFD fluid simulation, with a pressure loss of only 0.02 MPa, ensuring no impact on the normal water output of the water heater.

    The sensor innovatively integrates a self-cleaning wiper design, where the impeller automatically clears impurities from the flow channel with each rotation, preventing scale buildup from affecting sensitivity. The built-in chip features a temperature compensation algorithm that eliminates detection errors caused by water temperature changes, maintaining ±2% flow detection accuracy within a water temperature range of 4-90°C. It supports four sensitivity levels (switchable via magnetic rod proximity), compatible with the startup flow requirements of water heaters with different power ratings. The dual-signal output design (pulse signal + switch signal) allows direct connection to the mainboard or use as an independent water flow switch.

    Features

    ⚙️ Dual-Mode Output System

    • High-precision pulse mode: 2160 pulses per liter of water, resolution of 0.46 mL

    • Switch mode: adjustable startup flow (four levels: 0.3/0.5/0.8/1.2 L/min)

    🌡️ Intelligent Temperature Compensation Technology

    • Built-in NTC temperature sensor for real-time compensation

    • Full water temperature range accuracy of ±2% (industry standard ±5%)

    🛡️ Triple Dynamic Protection

    • Self-rotating scale-cleaning impeller (Patent No. ZL2022103****)

    • Ceramic bearings, never corrode

    • Shock-resistant structure passes 100g mechanical impact test

    🔌 Fully Compatible Interface

    • Output interface: 3-wire system (VCC/GND/Signal)

    • Connector: JST 2.5mm pitch / optional wires

    • Operating voltage: wide voltage range of DC 3.3-24V

    imgi_479_H0bc785bfb4084d9b9d9273551fa377236.jpg

    Product Parameter

    Item Technical Specifications
    Model FS-2208H
    Detection Principle Hall Magnetic Induction
    Housing Material PPS + 30% Glass Fiber (UL94 V-0)
    Impeller Material POM Magnetic Ring Integrated Molding
    Flow Range 0.3-10 L/min
    Startup Flow Adjustable Four Levels: 0.3/0.5/0.8/1.2 L/min
    Output Signal Pulse Frequency: 0-360Hz (Linear)
    Signal Output Open Collector (Maximum 100mA)
    Accuracy Class ±2% FS (with Temperature Compensation)
    Pressure Resistance 1.6 MPa Burst Pressure
    Operating Temperature Medium Temperature: 4-95°C; Ambient Temperature: -20-85°C

    FAQ

    Q1: How does the sensor prevent scaling in hard water areas?
    A: It employs three anti-scaling technologies:

    1. Impeller coated with nano-hydrophobic coating

    2. Flow channel mirror polishing (Ra0.2μm)

    3. Automatic high-speed self-cleaning twice a month (impeller idling at 3000 rpm)

    Q2: How to determine if the sensor is faulty?
    A: Diagnosis can be performed using the following methods:

    • Normal state: Multimeter detects pulse voltage fluctuations (0-Vcc variation) when water flows

    • Faulty state: Constant high/low voltage level

    • Reduced sensitivity: Significantly increased flow required for startup

    Q3: What should be noted during installation?
    A: Key installation requirements:

    1. Must be installed horizontally (tilt <5°)

    2. Water inlet direction must align with the arrow indicator

    3. A 100-mesh filter is recommended upstream

    4. Avoid installation at the highest point of the pipeline (to prevent air accumulation)

    Q4: Can it replace mechanical water flow switches?
    A: Fully compatible replacement with advantages including:

    1. No mechanical contacts, lifespan increased by 10 times

    2. Adjustable startup flow (fixed for mechanical switches)

    3. Provides flow data instead of just switch signals

    Q5: How to adjust sensitivity on-site?
    A: Steps for adjustment without disassembly:

    1. Use the included magnetic rod to approach the marked area on the sensor

    2. Each approach switches to the next level (LED indicator flashes for feedback)

    3. Four-level cycle: Green light (0.3L) → Blue light (0.5L) → Yellow light (0.8L) → Red light (1.2L)